Application and function

The float switch can be used as water level controller or limiter for steam generators as per TRD 401, 402 or 602. The product corresponds to the EU 2014/68/EU module B and has the CE-mark no. 0035 of the notified body. Applied standards as per EN 13445 / EN 12952 / EN 12953 / AD 2000 or ASME-Boiler.

Technical basic equipment

Material according to DIN or ASME
Protection as per DIN VDE 0470: IP54
Process connection: flanges as per DIN or ANSI
Magnetic switch type M130-KG (D-07-D-16324-0)
Cable gland according to DIN EN 50262: M20x1,5
Drain plug G ½

Available (optional) versions

Protection as per DIN VDE 0470: IP65
Process connection: welding end, Socket Welding
Level indication (signal lamps), data sheet D-07-D-16323-0
Ventilation screw
Drain valve AV500 or 520